I.   GENERAL GUIDE
...(OPERATING INSTRUCTIONS OF THE DIGITAL CONTROL SYSTEM)

[ 1] Digital Temperature window : Temperature display.
[ 2] Digital Timer window : Timer display. (Count down)
[ 3] Temperature setting key
[ 4] Key up : Press to set the temperature or time Up.
[ 5] Key down: Press to set the temperature or time Down.
[ 6] Time setting key
[ 7] Main Power on Signal
[ 8] Sauna Heating on Signal (Twinkling)
[ 9] Room Lamp Signal
[10] Main Power ON / OFF .
[11] Sauna Heating Start / Stop .
[12] Room Lamp ON / OFF . Top

 II.   USING THE DIGITAL CONTROL

  1. Turn on the Main Power (Press [10] button).
    At this time, Thermostat / Timer Window shows that the temperature which is inside of a sauna Cabin and the previous setting time.
  2. To set the temperature you desire (Press [3] button).
    Press [3] button - the temperature digits start to flash on the Temperature Window.
    Press key up or key down to set the temperature you desire.
    After setting temperature, press [3], to store the setting.
    ** Note when you setting the temperature or time, Sauna button [ 11] must be stopped. **
  3. To set the timer you desire (Press [6] button).
    Press [6] button - the timer digits starts to flash on the Timer Window.
    Press key up or down to setting the count-down timer you desire.
    After setting timer, press [6], to store the setting.
  4. To starting, press [11] to Heating Infrared Ceramic Heaters.
    * Sauna on Signal [8] will starts to flash.
    * While the timer operation (counting down), time digits counting down per a minutes.
    * Time passed away, Automatically power OFF and the Time digits converted to the setting.
    * From Start, Count-down passed away 10 minutes(pre-heating time), an electric buzzer sounds so that you may note and enjoying the sauna bath.

    Infrared Ceramic Heaters operating *** Temperature reaches up to setting, Heating operation automatically stopped.    
    *** When the temperature under setting, Heater operating will be automatically re-started during the timer.                                     
  5. Room lamp [12] is regardless of the Heating opration. Top

 III.   ERROR INDICATOR

The Error indicator 'E1, E2' appears on the temperature window, whenever any of the following conditions exist.

E1 : When the temperature reachs over 90กษ, ...  Heaters operating will be automatically stopped and Electric buzzer sounds.

E2 : When the Electrical Shortage, Breaking of Wire, Disconnection of digital sensor.... display 'E2' & buzzer sounds.

 

Top
  © Sunghospa.com All rights reserved.