I. GENERAL GUIDE
...(OPERATING INSTRUCTIONS OF THE DIGITAL CONTROL SYSTEM)
[ 1] Digital Temperature window : Temperature display.
[ 2] Digital Timer window : Timer display. (Count down)
[ 3] Temperature setting key
[ 4] Key up : Press to set the temperature or time Up.
[ 5] Key down: Press to set the temperature or time Down.
[ 6] Time setting key
[ 7] Main Power on Signal
[ 8] Sauna Heating on Signal (Twinkling)
[ 9] Room Lamp Signal
[10] Main Power ON / OFF .
[11] Sauna Heating Start / Stop .
[12] Room Lamp ON / OFF . Top
II. USING THE DIGITAL CONTROL
- Turn on the Main Power (Press [10] button).
At this time, Thermostat / Timer Window shows that the temperature
which is inside of a sauna Cabin and the previous setting time.
- To set the temperature you desire (Press [3] button).
Press [3] button - the temperature digits start to flash on
the Temperature Window.
Press key up or key down to set the temperature you desire.
After setting temperature, press [3], to store the setting.
** Note when you setting the temperature or time,
Sauna button [ 11] must be stopped. **
- To set the timer you desire (Press [6] button).
Press [6] button - the timer digits starts to flash on the Timer Window.
Press key up or down to setting the count-down timer you desire.
After setting timer, press [6], to store the setting.
- To starting, press [11] to Heating Infrared Ceramic Heaters.
* Sauna on Signal [8] will starts
to flash.
* While the timer operation (counting down), time digits
counting down per a minutes.
* Time passed away, Automatically power OFF and the
Time digits converted to the setting.
* From Start, Count-down passed away 10 minutes(pre-heating time),
an electric buzzer sounds so that you may note and enjoying the sauna
bath.
Infrared Ceramic Heaters operating
*** Temperature reaches up to setting,
Heating operation automatically stopped.
*** When the temperature under setting, Heater operating will
be automatically re-started during the timer.
- Room lamp [12] is regardless of the Heating opration. Top
III. ERROR INDICATOR
The Error indicator 'E1, E2' appears on the temperature window,
whenever any of the following conditions exist.
E1 : When the temperature reachs over 90กษ, ... Heaters operating
will be automatically stopped and Electric buzzer sounds.
E2 : When the Electrical Shortage, Breaking of Wire,
Disconnection of digital sensor.... display 'E2' & buzzer sounds.
|